Original Article

Vol. 26 No. 5 (2015): 2015.26.5-Turkish Journal of Gastroenterology

Sedation for gastrointestinal endoscopy with the application of target-controlled infusion

Main Article Content

Yi-Ting Chang
Tzung-Chieh Tsai
Huan Hsu
Yung-Ming Chen
Kuang-Piao Chi
Shih-Yen Peng

Abstract

Background/Aims: A majority of esophagogastroduodenoscopy (EGD) and colonoscopy procedures are performed under sedation, with the intravenous administration of a hypnotic agent combined with an opioid analgesic agent. The goal of our study was to establish the quality and plausibility of target-controlled infusion (TCI) as a sedation mechanism for upper and lower gastrointestinal (GI) endoscopies.<o:p></o:p>
 
Materials and Methods: A randomized, single-blinded, controlled clinical trial was arranged in a local community hospital. In total, 100 adult outpatients scheduled for upper and lower GI endoscopies were included and randomly allocated to a control group (n=50) and a TCI group (n=50). The sedation quality was assessed using the simplified quality of an anesthesia scoring system. Categorical parameters were compared using Pearson’s chi-square test. Continuous parameters that were normally distributed were further compared using Student’s t-test, and the others were compared using the Mann–Whitney test. <o:p></o:p>
 
Results: The significantly lower anesthesia quality score in the TCI group (12.2 vs. 12.7) indicated that the anesthesia quality was better in this group.<o:p></o:p>
 
 
Conclusion: This study showed that sedation using TCI for GI endoscopy provided safe and effective sedation and was associated with a better sedation quality. We believe that TCI can be used to provide routine sedation for patients receiving GI endoscopy.<o:p></o:p>

Article Details

Similar Articles

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 > >> 